Product information
The APC Replacement Battery Cartridge #2 (RBC2) is an original replacement battery from APC by Schneider Electric. In compatible UPS systems, it restores the original backup time when the old battery has deteriorated.
The battery is a maintenance-free, sealed lead-acid (VRLA) battery with 12 V and 7 Ah. It is designed for selected APC Back-UPS from the BK and BH series. The typical service life is 3 to 5 years, depending on temperature and usage. Installation instructions and information on the return of the old battery are included.
Important: Before purchasing, please check the nameplate or your UPS manual to see which replacement battery is specified. For example, the APC Back-UPS BX950MI and BX950MI-GR require the RBC17 (12 V, 9 Ah), not the RBC2. If you have any questions about compatibility, please contact us.
Product series: Back-UPS BX
Model: BX950MI
Product type: Line-Interactive UPS (Tower)
Power: 950 VA / 520 W
Rated output voltage: 230 V (configurable 220 V to 240 V)
Output frequency: 47–63 Hz (mains-synchronous transfer)
Waveform: Stepped approximation of a sine wave
Output connectors: 6 × IEC 60320 C13 (all with battery and surge protection)
Input voltage: 230 V
Input voltage range: 140–300 V
Input frequency: 50/60 Hz ±5 Hz (automatic detection)
Maximum input current: 10 A
Input connector: IEC 60320 C14
Cable length: 1.22 m
Battery type: Lead-acid battery (maintenance-free, sealed, VRLA)
Battery voltage: 12 V
Battery capacity: 9.0 Ah (108 Wh)
Typical battery life: 3 to 5 years
Charging time: approx. 8 hours (up to 90% in approx. 8 hours)
User-replaceable battery: Yes (replacement battery: RBC17, model-dependent)
Typical battery runtime at full load (520 W): approx. 1 minute
Typical battery runtime at 50% load (260 W): approx. 6.5 minutes
Interfaces: USB (Type B, for PC management), RJ45/RJ11 (for network/DSL/telephone)
Management software: APC PowerChute Personal Edition (for USB shutdown and management)
Surge protection: Yes
Energy absorption for surge protection: 273 J
Protection functions: Overvoltage, undervoltage, mains noise, short circuit, overload
Form factor: Tower
Dimensions (H × W × D): 16.0 × 12.0 × 35.5 cm
Weight: approx. 6.1 kg
Operating temperature: 0 °C to 40 °C
Storage temperature: −15 °C to 45 °C
Relative humidity during operation: 0% to 95%, non-condensing
Maximum operating altitude: 3,000 m
Noise level: approx. 40 dBA
Certifications: CE, CB, EAC, RoHS
Standards: EN/IEC 62040-1:2019/A11:2021, EN/IEC 62040-2:2006/AC:2006, EN/IEC 62040-2:2018
Protection rating: IP20
Warranty: 2 years (repair or replacement)
The APC Replacement Battery Cartridge #2 (RBC2) is an original replacement battery from APC by Schneider Electric. In compatible UPS systems, it restores the original backup time when the old battery has deteriorated.
The battery is a maintenance-free, sealed lead-acid (VRLA) battery with 12 V and 7 Ah. It is designed for selected APC Back-UPS from the BK and BH series. The typical service life is 3 to 5 years, depending on temperature and usage. Installation instructions and information on the return of the old battery are included.
Important: Before purchasing, please check the nameplate or your UPS manual to see which replacement battery is specified. For example, the APC Back-UPS BX950MI and BX950MI-GR require the RBC17 (12 V, 9 Ah), not the RBC2. If you have any questions about compatibility, please contact us.
Product series: Back-UPS BX
Model: BX950MI
Product type: Line-Interactive UPS (Tower)
Power: 950 VA / 520 W
Rated output voltage: 230 V (configurable 220 V to 240 V)
Output frequency: 47–63 Hz (mains-synchronous transfer)
Waveform: Stepped approximation of a sine wave
Output connectors: 6 × IEC 60320 C13 (all with battery and surge protection)
Input voltage: 230 V
Input voltage range: 140–300 V
Input frequency: 50/60 Hz ±5 Hz (automatic detection)
Maximum input current: 10 A
Input connector: IEC 60320 C14
Cable length: 1.22 m
Battery type: Lead-acid battery (maintenance-free, sealed, VRLA)
Battery voltage: 12 V
Battery capacity: 9.0 Ah (108 Wh)
Typical battery life: 3 to 5 years
Charging time: approx. 8 hours (up to 90% in approx. 8 hours)
User-replaceable battery: Yes (replacement battery: RBC17, model-dependent)
Typical battery runtime at full load (520 W): approx. 1 minute
Typical battery runtime at 50% load (260 W): approx. 6.5 minutes
Interfaces: USB (Type B, for PC management), RJ45/RJ11 (for network/DSL/telephone)
Management software: APC PowerChute Personal Edition (for USB shutdown and management)
Surge protection: Yes
Energy absorption for surge protection: 273 J
Protection functions: Overvoltage, undervoltage, mains noise, short circuit, overload
Form factor: Tower
Dimensions (H × W × D): 16.0 × 12.0 × 35.5 cm
Weight: approx. 6.1 kg
Operating temperature: 0 °C to 40 °C
Storage temperature: −15 °C to 45 °C
Relative humidity during operation: 0% to 95%, non-condensing
Maximum operating altitude: 3,000 m
Noise level: approx. 40 dBA
Certifications: CE, CB, EAC, RoHS
Standards: EN/IEC 62040-1:2019/A11:2021, EN/IEC 62040-2:2006/AC:2006, EN/IEC 62040-2:2018
Protection rating: IP20
Warranty: 2 years (repair or replacement)
APC Replacement Battery Cartridge #2 (RBC2) – UPS Replacement Battery, 12 V, 7 Ah, VRLA
- Regular price
- 96,99 €
- Sale price
- 96,99 €
- Regular price
-
Couldn't load pickup availability